- General Details
- Techical Info
- Order Enquiry
- Approval
- Catalog
- Related Products
The M36D is a digital column load cell designed for truck scales and weighbridge systems requiring stable digital signal transmission and long-term weighing accuracy.
With a maximum capacity of 40 tons, M36D digital column type load cell is suitable for most standard truck scale installations. The load cell is manufactured from high-strength alloy steel, optional stainless steel for corrosive or wash-down environments. The IP68 protection ensures dependable performance in demanding outdoor conditions.
Features
- Digital Communication
Digital signal transmission with strong anti-interference capability ensures weighing accuracy and simplifies system maintenance.
- IP68 protection
Designed for outdoor weighbridge installations with reliable sealing against water and dust.
- Alloy Steel or Stainless Steel
Available in different materials to suit industrial or corrosive environments.
- Improves the accuracy and consistency of multi-sensor truck scales
- Simpler wiring compared to analog systems
- Suitable for intelligent networked weighbridge systems
- Interchangeable with below models: H*MB C16A, M*ettler Toledo 0782(30t) , R*evere ASC | ASC2, Z*emic BM14G, F*lintec RC3
Models
| Part No. | 120247 | 120248 | 120249 | 120250 |
| M36i | 20t | 30t | 40t | 50t |
| Part No. | 120251 | 120252 | 120253 | 120254 |
| M36D | 10t | 20t | 30t | 40t |
| Class | C3 | |||
| IP | IP68 | |||
Why Choose a Digital Load Cell?
Compared with analog load cells, digital load cells offer:
- Stable digital signal transmission
- Better resistance to electrical interference
- Easier fault diagnosis
- Individual sensor monitoring
- Higher accuracy for large weighbridge systems
Applications
- Digital truck scales and weighbridges
- Intelligent weighing systems with data integration
- High-traffic vehicle weighing stations
- Industrial and commercial weighbridge installations
FAQ
1. How do I choose between a column load cell and a double ended beam load cell?
The choice mainly depends on the weighbridge structure and mounting design. Column load cells are commonly used in truck scales that require high overload resistance and easy vertical installation. Double ended beam load cells are typically selected for modular weighbridges where side forces and structural movement need to be better accommodated. Always choose a load cell that matches the weighbridge design specified by the manufacturer.
2. Can M36D digital load cell replace an existing truck scale load cell?
In many cases, yes. However, replacement compatibility depends on the load cell dimensions, mounting assembly, rated capacity, communication protocol and indicator compatibility. Before replacing an existing load cell, compare the mechanical drawings and electrical specifications or contact our technical team for compatibility confirmation.
3. What are the advantages of a digital load cell over an analog load cell?
Digital load cells provide digital signal transmission directly from the load cell, reducing electrical interference over long cable distances. They also simplify fault diagnosis because each load cell can be monitored individually, making maintenance faster in large weighbridge systems.
Capacity
10-40t
Sensitivity
2.0 ± 0.01mV/V
Accuracy
C3
Creep (30 Min)
± 0.016 – 0.023%F.S.
Zero Balance
± 1.5% Emax
TE* Zero
± 0.011 – 0.017%FS/10℃
TE* Span
± 0.015 – 0.023%FS/10℃
Input Resistance
700 ± 10Ω
Output Resistance
700 ± 5Ω
Insultation Resistance
≥5000mΩ(100VDC)
Opearting Tem Range
-35…70℃
Temp Compensation
-20…60℃
Safe Load
150% F.S.
Overload Limitation
200% F.S.
Recommended Excitation
5-12VDC
Protection
IP68
Contact form description text
CE
M36i OIML Canister Load Cell
With a capacity of up to 50 tons, the M36i analog load cell is ideal for stationary truck scales, industrial weighbridges and high-capacity vehicle weighing systems.
M9D Digital Truck Scale Load Cell
Digital double ended beam load cell is designed for modern truck scale and weighbridge systems requiring higher accuracy, improved signal stability and advanced diagnostics.
M9 M9M Double-ended Beam Load Cell
The analog double ended beam load cell is specifically engineered for truck scales and weighbridge systems requiring stable, accurate, and long-term reliable performance.